NorComp Inc.(9408)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Voltage - Rated DC Current Rating Color Factory Lead Time Ratings REACH SVHC Pbfree Code Connector Type Number of Positions Gender Contact Finish - Mating Orientation Contact Material Reach Compliance Code Ingress Protection JESD-609 Code Feature Applications Mounting Feature Shielding Current Rating (Amps) Shell Material Shell Finish Fastening Type Material Flammability Rating Shell Size - Insert Insert Material Contact Finish Thickness - Mating Backshell Material, Plating Cable Opening
860-X08-213R0R4 860-X08-213R0R4 NorComp Inc. $24.80
RFQ

Min: 1

Mult: 1

download VULCON™. Panel Mount, Through Hole -40°C~85°C 1 (Unlimited) Solder 50VAC 60VDC ROHS3 Compliant https://pdf.utmel.com/r/datasheets/norcompinc-860x08213r0r4-datasheets-4037.pdf Silver 14 Weeks Plug, Female Sockets 8 Gold X IP67 - Dust Tight, Waterproof Industrial Bulkhead - Front Side Nut Shielded 0.5A Brass Nickel Threaded UL94 V-0 M12-8 Polyamide (PA), Nylon 10.0μin 0.25μm
821B014-203RF01 821B014-203RF01 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 821B Panel Mount -40°C~200°C Tray 1 (Unlimited) Solder Cup 260V ROHS3 Compliant https://pdf.utmel.com/r/datasheets/norcompinc-821b002203rf01-datasheets-3945.pdf Silver 14 Weeks Receptacle, Female Sockets 14 Gold Keyed Copper Alloy IP50 - Dust Protected Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Bulkhead - Rear Side Nut Shielded Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
820B005-103R001 820B005-103R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 820B Bulkhead, Panel, Rear Side Nut Panel Mount -40°C~200°C Tray 1 (Unlimited) Solder Cup 280V ROHS3 Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-820b002103r001-datasheets-2475.pdf Silver 14 Weeks IP50 yes Plug, Male Pins 5 Gold Keyed Copper Alloy IP50 - Dust Protected Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Bulkhead - Rear Side Nut Shielded 6.5A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.323 (8.20mm)
820BR05-2S3R001 820BR05-2S3R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 820B Panel Mount, Through Hole, Right Angle -40°C~200°C Tray 1 (Unlimited) Solder 280V ROHS3 Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-820br022s3r001-datasheets-2979.pdf Silver 14 Weeks Receptacle, Female Sockets 5 Gold Keyed Copper Alloy IP50 - Dust Protected Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Bulkhead - Front Side Nut Shielded 6.5A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
821BR04-213R001 821BR04-213R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 821B Bulkhead, Panel, Through Hole Panel Mount, Through Hole, Right Angle -40°C~200°C Tray 1 (Unlimited) Solder 430V ROHS3 Compliant 2016 Black, Silver 14 Weeks IP50 yes Receptacle, Female Sockets 4 Gold Keyed Copper Alloy IP50 - Dust Protected Board Guide Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Bulkhead - Front Side Nut Shielded 10A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
821B008-173L501 821B008-173L501 NorComp Inc. $33.94
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 821B Free Hanging Free Hanging (In-Line) -40°C~200°C Tray 1 (Unlimited) Solder Cup 315V ROHS3 Compliant 2016 https://pdf.utmel.com/r/datasheets/norcompinc-821b003173l401-datasheets-0840.pdf Black, Silver 14 Weeks IP50 yes Plug, Male Pins 8 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Industrial, Instrumentation, Medical, Testing Equipment & Measurement, Telecommunications Shielded 5A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Brass, Chrome 0.169 ~ 0.205 (4.30mm ~ 5.20mm)
8P1P00417BGL421 8P1P00417BGL421 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00417bgl421-datasheets-5592.pdf Gray 14 Weeks no Plug, Male Pins 4 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Unshielded 8A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) 0.087 ~ 0.157 (2.20mm ~ 3.99mm)
822B012-103R001 822B012-103R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 822B Bulkhead, Panel, Rear Side Nut Panel Mount -40°C~200°C Tray 1 (Unlimited) Solder Cup 480V ROHS3 Compliant 2016 https://pdf.utmel.com/r/datasheets/norcompinc-822b006103r001-datasheets-7304.pdf Silver 14 Weeks IP50 yes Plug, Male Pins 12 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Rear Side Nut Shielded 7A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.531 (13.50mm)
822BR06-213R001 822BR06-213R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 822B Bulkhead, Panel, Through Hole Panel Mount, Through Hole, Right Angle -40°C~200°C Tray 1 (Unlimited) Solder 450V ROHS3 Compliant 2016 https://pdf.utmel.com/r/datasheets/norcompinc-822br12213r001-datasheets-7722.pdf Silver 14 Weeks IP50 yes Receptacle, Female Sockets 6 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Front Side Nut Shielded 12A Brass Nickel Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
860-004-213R004 860-004-213R004 NorComp Inc. $14.38
RFQ

Min: 1

Mult: 1

download VULCON™. Bulkhead, Front Side Nut, Panel Panel Mount, Through Hole -40°C~85°C Tray 1 (Unlimited) Solder 250V ROHS3 Compliant 2015 https://pdf.utmel.com/r/datasheets/norcompinc-860004213r004-datasheets-0615.pdf 125V 5A Silver 14 Weeks Dust Tight, IP67, Waterproof No SVHC no Plug, Female Sockets 4 Receptacle Gold A IP67 - Dust Tight, Waterproof Industrial, Medical Bulkhead - Front Side Nut Shielded 4A Brass Nickel Threaded UL94 V-0 M12-4 Polybutylene Terephthalate (PBT) 10.0μin 0.25μm
858-R03-103RLU1 858-R03-103RLU1 NorComp Inc.
RFQ

Min: 1

Mult: 1

download VULCON™. Free Hanging (In-Line) -40°C~85°C Tray Solder Cup 250V RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-858r03103rlu4-datasheets-8195.pdf Black, Silver 14 Weeks Receptacle, Male Pins 3 Gold A IP67 - Dust Tight, Waterproof Industrial, Medical Unshielded 4A Brass Nickel Threaded UL94 V-0 M12-3 Polybutylene Terephthalate (PBT) Flash 0.370 (9.40mm)
850-002-203RSS1 850-002-203RSS1 NorComp Inc.
RFQ

Min: 1

Mult: 1

download VULCON™. Free Hanging (In-Line) -40°C~85°C Tray Solder Cup 60V RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-850002203rss4-datasheets-1855.pdf Silver 14 Weeks Plug, Female Sockets 2 Gold Keyed Phosphor Bronze compliant IP67 - Dust Tight, Waterproof Coupling Nut Industrial, Medical Shielded 1A Brass Tin Threaded UL94 V-0 M5-2 Thermoplastic Polyurethane (TPU) Flash
854-006-203RLS1 854-006-203RLS1 NorComp Inc.
RFQ

Min: 1

Mult: 1

download VULCON™. Free Hanging (In-Line) -40°C~85°C Tray Solder Cup 30V RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-854a006103rls1-datasheets-7521.pdf Black, Silver 14 Weeks Plug, Female Sockets 6 Gold Phosphor Bronze compliant IP67 - Dust Tight, Waterproof Coupling Nut, Ground Industrial, Medical 1.5A Brass Nickel Threaded UL94 V-0 M8-6 Polybutylene Terephthalate (PBT) Flash
859-008-103R004 859-008-103R004 NorComp Inc. $10.87
RFQ

Min: 1

Mult: 1

download VULCON™. Bulkhead, Front Side Nut, Panel Panel Mount -40°C~85°C Tray 1 (Unlimited) Solder Cup 30V ROHS3 Compliant 2015 https://pdf.utmel.com/r/datasheets/norcompinc-859008103r001-datasheets-1221.pdf 125V 5A Silver 14 Weeks Dust Tight, IP67, Waterproof No SVHC no Receptacle, Male Pins 8 Gold A IP67 - Dust Tight, Waterproof Industrial, Medical Bulkhead - Front Side Nut Shielded 2A Brass Nickel Threaded UL94 V-0 M12-8 Polybutylene Terephthalate (PBT) 10.0μin 0.25μm 0.457 (11.60mm)
8P1P005200RRB01 8P1P005200RRB01 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Panel Mount -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p009200grb01-datasheets-0224.pdf Gray, Red 14 Weeks no Receptacle, Female Sockets 5 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Front Side Nut Unshielded 8A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
8P1P005210ARB01 8P1P005210ARB01 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Panel Mount, Through Hole -20°C~120°C Tray 1 (Unlimited) Solder 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p009210grb01-datasheets-6150.pdf Blue, Gray 14 Weeks no Receptacle, Female Sockets 5 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Front Side Nut Unshielded 8A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
8P1P00717BAL621 8P1P00717BAL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 450V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00417bgl421-datasheets-5592.pdf Blue, Gray 14 Weeks no Plug, Male Pins 7 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Unshielded 6A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) 0.197 ~ 0.236 (5.00mm ~ 6.00mm)
8P1P00717BAL521 8P1P00717BAL521 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 450V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00417bgl421-datasheets-5592.pdf Blue, Gray 14 Weeks no Plug, Male Pins 7 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Unshielded 6A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) 0.157 ~ 0.197 (4.00mm ~ 5.00mm)
8P1P00417NRL621 8P1P00417NRL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Gray, Red 14 Weeks no Plug, Male Pins 4 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 8A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.197 ~ 0.236 (5.00mm ~ 6.00mm)
8P1P00217BJL421 8P1P00217BJL421 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00417bgl421-datasheets-5592.pdf Gray, Yellow 14 Weeks no Plug, Male Pins 2 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) 0.087 ~ 0.157 (2.20mm ~ 3.99mm)
8P1P002200VRB01 8P1P002200VRB01 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Panel Mount -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p009200grb01-datasheets-0224.pdf Gray, Green 14 Weeks no Receptacle, Female Sockets 2 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Front Side Nut Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
8P1P002210VRB01 8P1P002210VRB01 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Panel Mount, Through Hole -20°C~120°C Tray 1 (Unlimited) Solder 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p009210grb01-datasheets-6150.pdf Gray, Green 14 Weeks no Receptacle, Female Sockets 2 Gold Keyed Copper Alloy IP50 - Dust Protected Bulkhead - Front Side Nut Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm
8P1P00217NGL421 8P1P00217NGL421 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Gray 14 Weeks no Plug, Male Pins 2 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.087 ~ 0.157 (2.20mm ~ 3.99mm)
8P1P00317BRL621 8P1P00317BRL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00417bgl421-datasheets-5592.pdf Gray, Red 14 Weeks no Plug, Male Pins 3 Gold Keyed Copper Alloy IP50 - Dust Protected Backshell, Strain Relief Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) 0.197 ~ 0.236 (5.00mm ~ 6.00mm)
858-012-103RLU1 858-012-103RLU1 NorComp Inc.
RFQ

Min: 1

Mult: 1

download VULCON™. Free Hanging (In-Line) -40°C~85°C Tray Solder Cup 30V RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-858012103rlu4-datasheets-1714.pdf Black, Silver 14 Weeks Receptacle, Male Pins 12 Gold A IP67 - Dust Tight, Waterproof Industrial, Medical Unshielded 1.5A Brass Nickel Threaded UL94 V-0 M12-12 Polybutylene Terephthalate (PBT) Flash 0.374 (9.50mm)
8P1P00317NNL621 8P1P00317NNL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 500V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Black, Gray 14 Weeks no Plug, Male Pins 3 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 10A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.197 ~ 0.236 (5.00mm ~ 6.00mm)
860-004-113R001 860-004-113R001 NorComp Inc.
RFQ

Min: 1

Mult: 1

download VULCON™. Panel Mount, Through Hole -40°C~85°C Tray Solder 250V RoHS Compliant https://pdf.utmel.com/r/datasheets/norcompinc-860004113r004-datasheets-1843.pdf Silver 14 Weeks Receptacle, Male Pins 4 Gold A IP67 - Dust Tight, Waterproof Industrial, Medical Bulkhead - Front Side Nut Shielded 4A Brass Nickel Threaded UL94 V-0 M12-4 Polybutylene Terephthalate (PBT) Flash
8P1P00917NNL521 8P1P00917NNL521 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 333V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Black, Gray 14 Weeks no Plug, Male Pins 9 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 3A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.157 ~ 0.197 (4.00mm ~ 5.00mm)
8P1P00917NVL621 8P1P00917NVL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 333V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Gray, Green 14 Weeks no Plug, Male Pins 9 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 3A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.197 ~ 0.236 (5.00mm ~ 6.00mm)
8P1P01017NJL621 8P1P01017NJL621 NorComp Inc.
RFQ

Min: 1

Mult: 1

download QUIK-LOQ™ 8P1P Free Hanging (In-Line) -20°C~120°C Tray 1 (Unlimited) Solder Cup 333V Non-RoHS Compliant 2017 https://pdf.utmel.com/r/datasheets/norcompinc-8p1p00917ngl421-datasheets-5598.pdf Gray, Yellow 14 Weeks no Plug, Male Pins 10 Gold Keyed Copper Alloy IP50 - Dust Protected e4 Unshielded 3A Polyacrylonitrile Butadiene Styrene (ABS), Polycarbonate (PC) Push-Pull Polyphenylene Sulfide (PPS) 7.00μin 0.178μm 0.197 ~ 0.236 (5.00mm ~ 6.00mm)

In Stock

Please send RFQ , we will respond immediately.